What Causes Industrial Coating Failure, and How Can It Be Prevented?
Most industrial coating failures trace back to five causes: poor surface preparation, a coating system that does not suit the environment, film applied too thin or cured incorrectly, gas escaping from galvanised steel during curing, and damage or contamination left untreated in service. Each one can be prevented at the specification stage, in the coating shop or through routine maintenance. Key Facts •Rust, mill scale, oil and old paint left on steel weaken adhesion; blasting and degreasing remove them before coating. •AS 4312 rates Australian sites by atmospheric corrosivity from C1 to CX. •AS/NZS 2312.1 guides the choice of coating systems for structural steel by expected life to first maintenance. •Powder manufacturers set film thickness and cure for each product; Interpon D2525 calls for 70–110 microns and 15 minutes at 190°C object temperature. •Outgassing from hot-dip galvanised steel can cause blisters and craters unless the steel is prepared and pre-baked. •...