What Causes Industrial Coating Failure, and How Can It Be Prevented?
Most industrial coating failures trace back to five causes:
poor surface preparation, a coating system that does not suit the environment,
film applied too thin or cured incorrectly, gas escaping from galvanised steel
during curing, and damage or contamination left untreated in service. Each one
can be prevented at the specification stage, in the coating shop or through
routine maintenance.
Key Facts
•Rust, mill scale, oil and old paint left on steel weaken
adhesion; blasting and degreasing remove them before coating.
•AS 4312 rates Australian sites by atmospheric corrosivity
from C1 to CX.
•AS/NZS 2312.1 guides the choice of coating systems for
structural steel by expected life to first maintenance.
•Powder manufacturers set film thickness and cure for each
product; Interpon D2525 calls for 70–110 microns and 15 minutes at 190°C object
temperature.
•Outgassing from hot-dip galvanised steel can cause blisters
and craters unless the steel is prepared and pre-baked.
•Sheltered, unwashed surfaces can degrade faster than
exposed ones.
What does coating
failure look like?
Most failures show up as one of
a few signs, and each points back to a likely cause:
|
Sign |
Likely cause |
How to prevent it |
|
Peeling or flaking |
Poor surface preparation or contamination |
Clean, degrease and abrasive blast before coating |
|
Blisters or pinholes on galvanised steel |
Outgassing during cure |
Sweep blast or chemically treat, then pre-bake |
|
Early rust at edges and corners |
Film too thin, or a system not suited to the site |
Specify for the corrosivity category; check film
build |
|
Soft, easily marked finish |
Under-curing |
Follow the powder's cure schedule at object temperature |
|
Rust staining in sheltered areas |
Salt and dirt build-up |
Regular cleaning and inspection |
Why is surface
preparation the most common cause?
Because a coating can only be as
sound as the surface under it. Contaminants left on the steel stop the powder
bonding, and the finish eventually lifts at that layer. Cleaning, degreasing
and abrasive blasting remove them and create a profile for adhesion. Surface
preparation is the first stage of Superior Coaters' four-stage process.
How does the wrong
system cause failure?
A finish that performs well in
an inland warehouse can break down early on a coastal wharf or in a chemical
plant. AS 4312 rates the site, and AS/NZS 2312.1 links each environment to
coating systems by expected life to first maintenance. Choosing the industrial
protective coating starts with that rating, not with colour or price.
What goes wrong in
application and curing?
Thin film leaves edges and
corners exposed; under-curing leaves a soft finish that scratches and weathers
early. Both are controlled by following the powder's data sheet, which sets the
film range and the time at object temperature. Thick steel needs longer to
reach temperature, so large fabrications need ovens big enough to cure the
whole piece evenly. Superior Coaters covers this in its article on coating heavy and oversized steel fabrications.
Why does galvanised
steel need special treatment?
Air and moisture trapped in the
zinc layer expand in the oven and push through the powder, leaving blisters or
craters. The American Galvanizers Association recommends a light sweep blast or
chemical treatment and a pre-bake before coating. Superior Coaters has
developed its own technique for powder coating hot-dip galvanised steel.
How do you prevent
failure once the asset is in service?
Clean on a schedule, inspect at
the same time and deal with chips before corrosion gets under the film. Pay
most attention to sheltered areas that rain does not rinse. Keep records, since
powder warranties can depend on documented maintenance.
Frequently Asked
Questions
What is outgassing?
Air or moisture trapped in a substrate, such as the zinc
layer of galvanised steel, that expands during curing and escapes through the
coating, leaving blisters or craters.
Which Australian Standards apply to industrial protective
coatings?
AS 4312 classifies site corrosivity, AS/NZS 2312.1 guides
coating systems for structural steel, and AS 4506 covers thermoset powder
coatings.
How do I choose the right industrial protective coating?
Start with the site's corrosivity category and the service
life you need, then ask your coater which pre-treatment and powder system they
propose and how the work will be inspected.
What to do next
Coating failures are cheaper to prevent than to fix. Superior Coaters operates a Quality Assurance System with full documentation, and provides industrial protective coating from Richlands for clients across Brisbane and the Gold Coast. Contact the team or call (07) 3375 6777 to discuss your project.

Comments
Post a Comment